For tram and light rail vehicle
An asymmetrical current collector type 120 ECI is designed to collect direct current from overhead lines with the voltage of 1,5 kV.
Opti onally equipped with the ADD (Automati c Drop Device) for safety issues. ADD system do not require air supply.
Mounti ng points opti ons:
Individually configured pantograph (adapted for Customer requirements).
Fully comply with EN 50206-2.
120 [km/h]
Temperature rangeClimatic Zone T3 (-25ºC to +45ºC)
Rated voltage1,5 kV DC
Rated current vehicle runningMax 1500 A
Maximum current vehicle at standstill200 A
Working range2440 mm
Housed height260 mm without insulators
Height at upper operating position2880 mm
Maximum extension~3130 mm
Static contact force60 to 120 N
Collector head profiles and length1700 mm DIN 43 267
Weight without izolators183 kg with ADD / 169 kg without ADD
Operation Electrical24V DC
Mounting points 3 options:520 x 1030 mm / 500 x 1000 mm / 850 x 1000 mm